Model Number | LT | G5 | G7 | P7 | P3 |
---|---|---|---|---|---|
Temperature Range |
-40 to 1000ºC (-40 to 1832ºF) |
250 to 2250ºC (482 to 4082ºF) |
300 to 900ºC (572 to 1652ºF) |
10 to 360ºC (50 to 680ºF) |
25 to 450ºC (77 to 842ºF) |
Spectral Response | 8 to 14 µm | 5 µm | 7.9 µm | 7.9 µm | 3.43 µm |
System Accuracy |
for Tmeas > 0°C (32°F): ±1% of reading or ±1.0°C (2.0°F) for Tmeas ≤ 0°C (32°F): ±[1.0°C + 0.1* (0°C – Tmeas )] with Tmeas in °C; ±[2.0°F + 0.1* (32°F – Tmeas )] with Tmeas in °F |
for Tmeas > 75°C (167°F): ±(3°C + 1% of reading) | |||
Repeatability | ±0.3°C (0.6°F) or 0.3% of reading | ±1°C (2°F) or 0.5% of reading | |||
Response Time | LT-07, LT-15, LTD-04: 150ms LT-30, LTB-30: 30ms LT-50, LT-70: 130ms | G5-30, G5-70: 60ms | G7-70: 130ms | P7-30: 130ms | P3-20: 130ms |
Optical Resolution (D:S) | LTD-04: 4:1 LT-07: 7:1 LT-15: 15:1 LT-30, LTB-30: 33:1 LT-50: 50:1 LT-70: 70:1 | G5-30: 33:1 G5-70: 70:1 | G7-70: 70:1 | P7-30: 33:1 | P3-20: 20:1 |
Focus Distance | LT-07: CFO 50mm (2in) LT-15, LTD-04: SFO 1520mm (60in) LT-30, LTB-30: SFO 1520mm (60in) CF1 76mm (3in) CF2 200mm (7.9in) LT-50: SFO 1520mm (60in) CF2 200mm (7.9in) LT-70: SF2 1250mm (49in) CF2 200mm (7.9in) |
G5-30: SFO 1520mm (60in) G5-70: SF2 1250mm (49in) |
G7-70: SF2 1250mm (49in) |
P7-30: SF0 1520mm (60in) |
P3-20: SF4 500mm (20in) |
Smallest Measurement Spot | LT-07: CF 7.1mm (0.28in) LT-30, LTB-30: CF1 2.3mm (0.09in) CF2 6.1mm (0.24in) LT-50: CF2 4mm (0.16in) LT-70: SF2 17.9mm (0.7in) CF2 2.9mm (0.11in) |
G5-70: SF2 17.9mm (0.7in) |
G7-70: SF2 17.9mm (0.7in) |
||
Standards and Compliance |
EC – Directive 2014/30/EU – EMC EC – Directive 2011/65/EU – RoHS Compliance amended by Directive (EU) 2015/863 EC – Directive 2014/34/EU – ATEX valid for models: T40-xx-xx-xxx-x-IS EC – Directive Nr. 1907/2006 – REACH amended by Directive (EU) 2020/2096 EN 61326-1: 2013 - Electrical measurement, control and laboratory devices - Electromagnetic susceptibility (EMC) EN 50581: 2012 - Technical documentation for the evaluation of electrical products with respect to restriction of hazardous substances (RoHS) EN 60079-0: 2019 Risk of explosion – part 0: general requirements (ATEX) EN 60079-11: 2012 Risk of explosion – part 11: device protection by intrinsic safety “I” (ATEX) UKCA - Conforms to UK Conformity. Except for units with intrinsically-safe rating. KCC - Electromagnetic Compatibility Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & Communication Equipment) |
Model Number | MT | HT | 3M | 2M | 1M | |
---|---|---|---|---|---|---|
Temperature Range |
250 to 2250ºC (482 to 4082ºF) |
500 to 2000ºC (932 to 3632ºF) |
100 to 600ºC (212 to 1112ºF) |
250 to 1400ºC (482 to 2552ºF) |
500 to 2300ºC (932 to 4172ºF) |
|
Spectral Response | 3.9 µm | 2.2 µm | 2.3 µm | 1.6 µm | 1 µm | |
System Accuracy |
for Tmeas > 0°C (32°F): ±1% of reading or ±1.0°C (2.0°F) for Tmeas ≤ 0°C (32°F): ±[1.0°C + 0.1* (0°C – Tmeas )] with Tmeas in °C; ±[2.0°F + 0.1* (32°F – Tmeas )] with Tmeas in °F |
±(2°C + 0.5% of reading) | ||||
Repeatability | ±0.3°C (0.6°F) or 0.3% of reading | ±1°C (2°F) or 0.25% of reading | ||||
Response Time |
MT-30, MT-70: 130 ms |
HT-60: 130 ms |
3M-70: 20ms |
2M-150, 1ML-150, 1MH-150: 10ms |
||
Optical Resolution (D:S) |
MT-30: 33:1 MT-70: 70:1 |
HT-60: 60:1 |
3M-70: 70:1 |
2M-150, 1ML-150, 1MH-150: 150:1 |
||
Focus Distance | MT-30: SF0 1520mm (60in) CF1 76mm (3in) CF2 200mm (7.9in) MT-70: SF2 1250mm (49in) CF1 76mm (3in) CF2 200mm (7.9in) | HT-60: SFO 1520mm (60in) CF1 76mm (3in) CF2 200mm (7.9in) | 3M-70: SFO 1520mm (60in) CF2 200mm (7.9in) |
2M-150, 1ML-150, 1MH-150: SFO 1520mm (60in) CF2 200mm (7.9in) |
||
Smallest Measurement Spot |
MT-30: CF1 2.3 mm (0.09 in) CF2 6.1 mm (0.24 in) MT-70: SF2 17.9 mm (0.7 in) CF1 1.1 mm (0.04 in) CF2 2.9 mm (0.11 in) |
HT-60: CF1 1.3mm (0.05in) CF2 3.3mm (0.13in) |
3M-70: CF2 2.9mm (0.11in) |
2M-150, 1ML-150, 1MH-150: SFO 10.1mm (0.4in) CF2 1.3mm (0.05in) |
||
Standards and Compliance |
EC – Directive 2014/30/EU – EMC EC – Directive 2011/65/EU – RoHS Compliance amended by Directive (EU) 2015/863 EC – Directive 2014/34/EU – ATEX valid for models: T40-xx-xx-xxx-x-IS EC – Directive Nr. 1907/2006 – REACH amended by Directive (EU) 2020/2096 EN 61326-1: 2013 - Electrical measurement, control and laboratory devices - Electromagnetic susceptibility (EMC) EN 50581: 2012 - Technical documentation for the evaluation of electrical products with respect to restriction of hazardous substances (RoHS) EN 60079-0: 2019 Risk of explosion – part 0: general requirements (ATEX) EN 60079-11: 2012 Risk of explosion – part 11: device protection by intrinsic safety “I” (ATEX) UKCA - Conforms to UK Conformity. Except for units with intrinsically-safe rating. KCC - Electromagnetic Compatibility Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & Communication Equipment) |
|||||
Thermalert 4.0 Model Spectral Response |
Applications |
---|---|
LT 8-14 µm |
Thick plastics, asphalt, carpeting, coated paper, thermoforming, food, coke, coal, cement |
G5 5 µm |
Glass surface temperature for bending, tempering, annealing and sealing |
G7 7.9 µm |
Ultra-thin drawn glass |
P3 3.43 µm |
Extrusion and converting of thin films: polyethylene, polypropylene, and polystyrene |
P7 7.9 µm |
Production and converting of films of polyester (PET), fluoroplastic, Teflon®, acrylic, nylon (polyamide) |
MT 3.9 µm |
Furnace refractory, flame hardening and brazing |
HT 2.2 µm |
Ferrous and nonferrous metals, induction heating, furnaces, laboratory research |
1M 1 µm |
Semiconductor, metals forging, molten glass |
2M 1.6 µm |
Non ferrous and unoxidized metals, galvanizing lines and steel annealing |
3M 2.3 µm |
Rolling mills, wire coating and annealing, laser welding, plastic tubing extensions |
C02 4.24 μm |
Flame or flue gas temperature measurement for incineration plants, boilers or power station |
C0 4.64 μm |
Flame or flue gas temperature measurement for incineration plants, boilers or power station |
NOX 4.47 μm |
Flame or flue gas temperature measurement for incineration plants, boilers or power station |
Industry | Application | Atex Type of Certification |
---|---|---|
Steel | Galvanizing, annealing, plating and coating with hydrogen atmosphere |
Gas II 2G Ex ib IIC T4 Gb |
Solar | Hydrogen reduction |
Gas II 2G Ex ib IIC T4 Gb |
Petrochemical | Sulfur recovery, boilers, crackers, reactors, pipes, flare control |
Gas II 2G Ex ib IIC T4 Gb |
Chemical | Fertilizer, starch, alcohols, flour, vinyl |
Gas II 2G Ex ib IIC T4 Gb |
Fire detection | Offshore installations, storage areas, indoor coke handling, dust extraction |
Dust II 2D Ex ib IIIC T135°C Db IP65 |
Storage terminals | Storage of coal, wood pellets, sulfur, petroleum coke, starch, fluids |
Dust II 2D Ex ib IIIC T135°C Db IP65 |