Inch-Metric: | Inch/Metric |
Measuring range: | 16 mm |
Traverse: | 17.5 mm |
Measuring speed: |
0.25 mm/s; 0.5 mm/s; 0.75 mm/s; 1.0 mm/s |
Functions: | Switchable between 25 languages: Japanese, English, German, French, Italian, Spanish, Portuguese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch, Korean, Traditional Chinese, Simplified Chinese, Slovenian, Russian, Romanian, Bulgarian, Finnish, Thai, Vietnamese, Indonesian, Malaysian |
Cable length: | 1 m |
Detector measuring force: | 0.75 mN |
Stylus tip angle: | 60° |
Stylus tip radius: | 2 µm |
Measuring method: | Differential inductance |
Range: | 360 µm |
Stylus: | Diamond Tip |
Skid radius: | 40 mm |
Profiles: | Primary Profile (P), Roughness Profile (R), R-Motif, DF-Profile |
Roughness standard: | EN ISO 21920, EN ISO 4287, EN ISO 13565, EN ISO 12085, VDA 2006, JIS, ASME |
No. of sampling length (L): | x1 - x10 |
Digital filter: | Gauss, 2CR75, PC75 |
Cut-off length: |
λc : 0.08 mm; 0.25 mm; 0.8 mm; 2.5 mm; 8 mm λs : 2.5 µm; 8 µm; 25 µm |
Auto-sleep: | The standby time in battery mode can be set between 10 and 600 seconds |
Tolerance: | Coloured upper / lower limit |
Mass: | 510 g |
Power supply: | Via AC adapter, rechargeable battery |