Description
Fluke Raytek® Compact GP Infrared Pyrometer
General purpose, compact, two-piece temperature monitoring system
Versatile. Compact. Value-priced.
-
Improve process control with instant noncontact temperature readings
-
Easily configure sensor parameters through display monitor
-
Choose from the standard or close focus optics
-
AVAILABLE IN APAC (ASIA-PACIFIC) AND AMERICAS ONLY
Raytek GP infrared pyrometers provide process temperature control in hard-to-reach, small or distant targets in temp range from -18 to 538°C (0 to 1000°F).
Description
The GP Series, consisting of GPR and GPS models, is a versatile, two-piece temperature monitoring system that combines a compact, value-priced monitor with an infrared sensing head. The heart of the system is the 1/8 DIN GP monitor which provides advanced infrared processing capabilities including peak and valley hold, averaging, and a user-adjustable offset.
The Compact GPR model is available with standard or close focus optics and provides target temperature readings with 1% accuracy.
In addition, the GPS model features laser sighting and standard optical Distance to Spot (D:S) ratio of 50:1, allowing for easier sensor alignment in hard-to-reach, small or distant targets. The GPS integrated coaxial Class 2 laser is connected to the remote activation switch box via the included 4 m (13 ft) cable. An additional 8 m (26 ft) of cable is also included to connect the switch box to the GP monitor.
Key Features:
-
Read temperature ranges from -18 to 538°C (0 to 1000°F)
-
Available with standard or close focus optics
-
Withstand ambient temperatures without cooling: monitor up to 50°C (120ºF) and the sensing head up to 65°C (150°F) .
-
Accessories for air purging and water/air cooling
-
Compact 1/8 DIN digital monitor with large 4-digit display
-
Monitor and sensor functions configured on front panel
-
Response time: 300 mSec
-
Adjustable emissivity and T-ambient parameters
-
Adjustable dual setpoints, deadband alarm outputs and optional mechanical relays
-
Field interchangeable sensing heads
Technical Specifications
Model Number |
GPR Standard Focus |
GPR Close Focus |
GPS Standard Focus |
GPS Close Focus |
Temperature Range |
-18° to 538°C
(0 to 1000° ºF) |
Spectral Response |
8 to 14 μm |
System Accuracy |
±1% of reading or ±1°C (2°F), whichever is greater, @23°C ±5°C (73°F ±9°F) |
Repeatability |
±0.5% of measured value or ±1°C (2°F), whichever is greater |
Optical Resolution (D:S) |
35:1 |
30 : 1 |
50 : 1 |
45 : 1 |
Response Time |
300 mSec |
Emissivity |
Adjustable; 0.10 to 1.09 for all models |
Signal Processing |
Peak and valley hold (up to 998 sec, 999=infinite hold with external reset).
Variable averaging filter (up to 60 seconds). T-ambient: fixed background ambient temperature compensation |
Ambient Temperature |
0°C to 65°C (32°F to 150°F)
with optional water cooling: 0°C to 177°C (32°F to 350°F)
with optional air cooling: 0°C to 120°C (32°F to 250°F)
GPS laser shuts off automatically at 50°C (120°F) |
Storage Temperature |
-30°C to 65°C (-22°F to 150°F) |
Environmental Rating |
IP 65 (IEC 529); NEMA-4 |
Monitor Specifications
Environmenal Rating |
GP Front Panel IP54 (IEC 529); NEMA-12 |
Ambient Temperature Range |
0 to 50°C (32 to 120°F |
Storage Temperature |
-30 to 65°C (-22 to 150°F) |
GP Monitor Dimensions |
1/8 DIN x 120 mm (1.75 x 3.63 x 4.75 in) |
GP Monitor Weight |
320 g (0.7 lbs) |
Applications
Compact GP pyrometers can be used across numerous industries and are ideal for a variety of OEM and end-user manufacturing applications including the list below and many others.
-
Paper Processing and Converting including: printing, coating, laminating, drying/curing
-
Plastic Processing
-
Asphalt
-
Pharmaceuticals
-
Textiles
Accessories
Each GP sensor system is comprised of the GPR or GPS sensing head, the 1/8 DIN monitor, and an additional 8 m (26 ft) connector cable.
Accessories for GPR/GPS Sensing Heads
-
Accessory air purge collar to keep lens clean (XXXTXXACAP)
-
Accessory conduit adapter, adapts sensor threads to .5 in. NPT (XXXTXXACCA)
-
Accessory pipe adapter, adapts sensor threads to 1.5 in. NPT (XXXTXXACPA)
-
Accessory right angle mirror, provides perpendicular view of target in tight installations (XXXTXXACRA)
-
Optional air/water cooled housing for installation in environments up to 177ºC (350ºF)
-
Optional NIST traceable calibration certificate
Accessories for GP Monitor
-
Accessory mounting bracket for sub-panel installation (XXXGPACFB)
-
Accessory solid state relays, 10 Amp AC (X XXGPSSRAC)
-
Optional 3A mechanical relays (RAYGPCM must be specified at time of order)