KROHNE OPTIBAR 5060 eDP Electronic differential pressure transmitter for level, differential pressur

KROHNE OPTIBAR 5060 eDP Electronic differential pressure transmitter for level, differential pressur

Category: Pressure Transmitters Available
For more information, visit our official website at improtechonline.com

Description

Overview

The OPTIBAR 5060 eDP is a dual pressure transmitter version for electronic differential pressure measurement. It is particularly suitable for level, density and DP applications with closed vessels as well as density compensated level measurement in open tanks and tanks vented to atmospheric pressure. In some applications electronic differential pressure measurement can be an alternative to the use of classical differential pressure transmitters.The main advantage of an eDP transmitter is its cost-efficient connection to the vessel. Smaller process connections without capillaries with a maximum distance of up to 25 m / 75 ft between the top and the bottom tap save cost and installation time. The electronic DP measurement loses its edge over a classical DP measurement in applications at higher gas pressures for which the classical differential pressure transmitters OPTIBAR DP 7060 or OPTIBAR DP 3050 are most suitable.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Free combination of OPTIBAR PM 5060 and OPTIBAR PC 5060 transmitters in a primary/secondary sensor system: configuration with metallic and/or ceramic diaphragms
  • No need for capillaries:
    • much smaller process connections (from G½) possible as compared to installation with capillary tube attachment
    • connection via signal cables instead of oil filled capillaries
    • thermal insulation not required
    • extremely fast step response times of less than 85 ms
    • less maintenance
  • Various housing materials available: plastic, aluminium, stainless steel (precision casting or electro-polished)
  • Quick setup for all applications
  • Ex ia, Ex d, Ex t approvals
  • SIL 2/3 certified by TÜV Rheinland: remote activation of SIL mode via display, DTM or Bluetooth
  • Many other approvals, e.g. 3A, EHEDG for the food industry, DNV GL for the marine industry
  • Available with a wide range of hygienic process connections
  • Extensive diagnostic and parameterisation functions
  • Wireless Bluetooth communication via smartphone or tablet (in conjunction with the Bluetooth display and adjustment module and the OPTICHECK Pressure Mobile app)

Specifications

Depending on selected device configuration

General information

Product type Pressure transmitter
Product family name OPTIBAR
Product positioning For level, differential pressure and density applications
Product variants

 

Measurement principle Hydrostatic
Measured media Liquids, Gases
Measuring point Pressurised tank

Operating conditions

Process pressure max. 100 bar/
1450 psi
Process temperature -40…+150°C/
-40…+302°F
With optional diaphragm seals up to +400°C / +752°F (only in combination with metallic diaphragms)

Materials

Diaphragm Ceramic (Al2O3), Austenitic stainless steel (1.4404/316L), Nickel-chrome-molybdenum-tungsten alloy (2.4819/Alloy C276), Cobalt-Chromium-Nickel-Molybdenum alloy (2.4711 / Alloy 1058)
Fill fluid Halocarbon oil, Dry measuring cell (without fill fluid), Food grade oils (FDA listed), Medical grade white oil (FDA conform)
Measuring cell seal Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM), Perfluoroelastomer rubber (FFKM), Without (fully welded)

Process connections

Thread connections

Male:
G½ (EN 837-1)
G½, G1, G1½, G2 (DIN 3852)
G½ (DIN 3852, 11 mm bore)
G½, G¾ front flush (DIN 3852)
G1 front flush (cone 40°, cone 33.4°)
Hygienic G1 for hygienic adapters
½ NPT (11 mm bore)
1 NPT front flush
¼ NPT, ½ NPT, 1½ NPT, 2 NPT
M20 x 1.5 (EN 837-1)


Female:
G½, G¼ (DIN 3852)
½ NPT, ¼ NPT

Hygienic adapters

Clamp (DIN 32676): DN25, DN40, DN50
Clamp (ISO 2852): 25, 40, 51
Tri-Clamp: 1'', 1½'', 2'', 3''
Hygienic fitting with compression nut: F40
Collar ferrule (SMS 1147): 25 mm, 38 mm, 51 mm
Collar ferrule (DIN 11851): DN25, DN40, DN50
Collar ferrule (DIN 11864-1A): DN40, DN50
Flange with collar (DIN 11864-2A): DN40, DN50
Aseptic clamp union (DIN 11864-3A): DN40, DN50
VARIVENT®: N, F
NEUMO BioControl®: DN25, DN50, DN65, DN80
NEUMO BioConnect®: DN80 DRD and others

Approvals/Standards

Certificates/Approvals Others Pressure Equipment Directive (PED)
Certificates/Approvals Ex ATEX, IECEx, NEPSI
Certificates/Approvals Hygienic FDA, 3A, EHEDG, EC 1935/2004
Certificates/Approvals Marine CCS, DNV, GL, NK
Certificates/Approvals Safety SIL 2/3

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA, Bluetooth
 

More detail about TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD Industrial Automation Supplier Malaysia, Flow Meter Supply Penang, Pressure Transmitter Supplies Butterworth ~ TECH IMPRO AUTOMATION SOLUTION SDN BHD
Contact Us flagMalaysia