The OPTIBAR P 2010 is an ultra-compact pressure transmitter with flush diaphragm for hygienic pressure and level applications in the food and beverage as well as in the pharmaceutical industry. It is perfectly suited for front-flush and aseptic installation. The versatile pressure and level transmitter provides a repeatable measuring signal that is stable over the long term, even with regular SIP/CIP cleaning cycles, while simultaneously guaranteeing a high degree of chemical resistance to process and cleaning solutions.
The modular design of the OPTIBAR P 2010 allows combining a wide range of fully welded process connections with a variety of filling media and electrical connections so as to accommodate virtually any hygienic requirement. Optional cooling fins can be added to handle continuous process temperatures up to +300°C / +572°F.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
Depending on selected device configuration
Product type | Pressure transmitter |
Product family name | OPTIBAR |
Product positioning | For hygienic pressure and level applications |
Measurement principle | Hydrostatic |
Measured media | Liquids, Gases |
Measuring point | Open tank |
Process pressure |
max. 40 bar/ 580 psi |
Process temperature |
-40…+150°C/ -40…+302°F |
Diaphragm | Austenitic stainless steel (1.4435/316L) |
Fill fluid | Silicone oil, Food grade oils (FDA listed) |
Measuring cell seal | Fluoroelastomer rubber (FKM), Perfluoroelastomer rubber (FFKM) |
Thread connections |
Male: Hygienic G½, G1 for hygienic adapters G½, G¾, G1 (DIN 3852) |
Hygienic adapters |
Clamp (DIN 32676): DN25, DN32, DN40, DN50 Clamp (ISO 2852): 25, 38 51 Tri-Clamp: ½'', ¾'', 1'', 2'' Collar ferrule (DIN 11851): DN25, DN40, DN50 VARIVENT® N |
Certificates/Approvals Others | Pressure Equipment Directive (PED) |
Certificates/Approvals Ex | ATEX, IECEx |
Certificates/Approvals Hygienic | FDA, 3A, EC 1935/2004 |
Analogue outputs | 0…10 VDC, 4…20 mA |